Int 0592-2011
Filtering soot from incoming air in buildings.
IntroductionEnactedCommittee on Housing and Buildingsintroduced 2011-06-14Local Law 2011/072
Enacted as Local Law 2011/072.
Official record · Legistar
Agenda: 2011-06-14Passed: 2011-12-27Enacted: 2011-12-27
Committee on Housing and Buildings — Department of Housing Preservation and Development, Department of Buildings and rent regulation.
How it compares
24% of similar bills passed
12 passed · 38 died
This bill: 176 days in committee
Similar bills: median 597 days · 124 days when passed
Compared against 50 Introduction bills in Committee on Housing and Buildings.
Ranked by how closely each matches this bill's topic — closest first:
Int 1459-2019
Standards for natural ventilation.
1037dFiled
Int 1038-2009
Carbon monoxide and smoke detecting devices.
183dFiled
Int 0070-2010
Carbon monoxide and smoke detecting devices.
1399dFiled
Int 0222-1998
Blocked Flue Cut-Off Switches Installation
1404dFiled
Int 0750-2008
Indoor asthma allergen hazards in residential dwellings.
624dFiled
Int 1111-2013
Smoke Alarms
112dEnacted
+ 44 more comparable bills
Sponsors (19)
Lifecycle
IntroducedIntroduced by Council
2011-06-14 · City Council
ActionReferred to Comm by Council
2011-06-14 · City Council
HeardHearing Held by Committee
2011-06-21 · Committee on Housing and Buildings
HeldLaid Over by Committee
2011-06-21 · Committee on Housing and Buildings
HeardHearing Held by Committee
2011-12-08 · Committee on Housing and Buildings
ActionAmendment Proposed by Comm
2011-12-08 · Committee on Housing and Buildings
ActionAmended by Committee
2011-12-08 · Committee on Housing and Buildings
AdvancedApproved by Committee
2011-12-08 · Committee on Housing and Buildings
AdvancedApproved by Council
2011-12-08 · City Council
ActionSent to Mayor by Council
2011-12-08 · City Council
HeardHearing Held by Mayor
2011-12-27 · Mayor
AdvancedSigned Into Law by Mayor
2011-12-27 · Mayor
ActionRecved from Mayor by Council
2011-12-27 · City Council
Votes (15)
Aye (13)
Erik Martin DilanLeroy G. Comrie, Jr.Elizabeth S. CrowleyLewis A. FidlerJames F. GennaroRobert JacksonBrad S. LanderMelissa Mark-ViveritoRosie MendezJames S. OddoJoel RiveraJumaane D. WilliamsLetitia James
Absent (2)
Gale A. BrewerEric A. Ulrich
Heard at (5)
City Council · 2011-12-08 · 1:30 PM · Council Chambers - City Hall
Committee on Housing and Buildings · 2011-12-08 · 10:30 AM · 250 Broadway - Committee Rm, 14th Fl.
Committee on Housing and Buildings · 2011-09-21 · 10:30 AM · 250 Broadway - Committee Rm, 14th Fl.
Committee on Housing and Buildings · 2011-06-21 · 1:00 PM · 250 Broadway - Committee Rm, 16th Fl.
City Council · 2011-06-14 · 1:30 PM · Emigrant Savings Bank - 49-51 Chambers Street
Attachments (11)
- Int. No. 592 - 6/14/11
- Committee Report 6/21/11
- Hearing Testimony 6/21/11
- Hearing Transcript 6/21/11
- Committee Report 12/8/11
- Hearing Transcript 12/8/11
- Committee Report - Stated Meeting
- Hearing Transcript - Stated Meeting 12-8-11
- Fiscal Impact Statement
- Mayor's Letter
- Local Law
Full text
Be it enacted by the Council as follows:
Section 1. Section MC 605 of the New York city mechanical code, as added by local law number 33 for the year 2007, is amended by adding a new subsection 605.2.1 to read as follows:
605.2.1 Standards for air-handling units. Air-handling units of mechanical ventilation systems, any portion of which provide outdoor air ventilation, shall be equipped with a particulate matter filtration system in accordance with ASHRAE 62.1 or ASHRAE 62.2 and shall have a minimum efficiency reporting value (MERV) of 11 or greater in accordance with ASHRAE 52.2.
Exceptions:
1. This section shall not apply to the alteration or repair of a mechanical ventilation system that was installed prior to January 1, 2013 unless such alteration or repair includes the replacement or addition of an air-handling unit in such system.
2. This section shall not apply to the replacement of an air handling unit in a mechanical ventilation system installed prior to January 1, 2013 if the department determines that the design of such replacement air-handling unit cannot be made to comply with the allowable fan system power limitations of the New York City Energy Conservation Code or ASHRAE 90.1.
3. This section shall not apply to any air-handling unit with a design capacity of less than 5,000 cfm.
§2. The list of referenced standards of ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) as set forth in chapter 15 of the New York city mechanical code is amended by adding three new standards to read as follows:
ASHRAE American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta, GA 30329-2305
________________________________________________________________________________________________
Standard
Reference
Number Title
________________________________________________________________________________________________
52.2 - 2007 Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size
62.1 - 2010 Ventilation for Acceptable Indoor Air Quality
62.2 - 2010 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings
§3. This local law shall take effect January 1, 2013, except that the commissioner of buildings shall take such actions as are necessary for its implementation, including the promulgation of rules, prior to such effective date.
JH/JTB/TME
LS 2497
11/30/11 6:49pm