Int 0258-1998
Air Admittance Valves in Dwellings
IntroductionFiledCommittee on Housing and Buildingsintroduced 1998-03-18
Filed — closed without being enacted.
Official record · Legistar
Agenda: 1998-03-18Passed: 2001-12-31
Committee on Housing and Buildings — Department of Housing Preservation and Development, Department of Buildings and rent regulation.
How it compares
22% of similar bills passed
11 passed · 39 died
This bill: 1383 days in committee
Similar bills: median 660 days · 123 days when passed
Compared against 50 Introduction bills in Committee on Housing and Buildings.
Ranked by how closely each matches this bill's topic — closest first:
Int 0247-1998
Gas Detecting Devices, Installation
1384dFiled
Int 0428-2003
Installation of sprinkler systems in certain residential occupancies.
265dFiled
Int 1459-2019
Standards for natural ventilation.
1037dFiled
Int 0750-2008
Indoor asthma allergen hazards in residential dwellings.
624dFiled
Int 1111-2013
Smoke Alarms
112dEnacted
Int 0332-2006
Issuance of certificates of occupancy for one-, two- or three-family dwellings.
1331dFiled
+ 44 more comparable bills
Sponsors (3)
Archie W. Spigner(prime)
Lucy Cruz
Sheldon S. Leffler
Lifecycle
IntroducedIntroduced by Council
1998-03-18 · City Council
ActionReferred to Comm by Council
1998-03-18 · City Council
ActionPrinted Item Laid on Desk
1998-04-06 · Legislative Documents Unit
ClosedFiled (End of Session)
2001-12-31 · City Council
Full text
Be it enacted by the Council as follows:
Section 1. This list of referenced national standards of reference standard RS-16 of the appendix to chapter one of title twenty-seven of the administrative code of the city of New York is amended in part to add the following:
ASSE 1050. Performance Requirements for Air Admittance Valves for Plumbing Drain, Waste and Vent Systems Stack Type Devices...............................1991
ANSI/ASSE 1050. Performance Requirements for Air Admittance Valves for Plumbing Drainage Systems -- Fixture and Branch Devices.......................1996
�2. Section P100.0 of reference standard RS-16 of the appendix to chapter one of title twenty-seven of the administrative code of the city of New York is amended in part to add the following definition:
Air admittance valve. -- A one-way valve designed to allow air to enter the plumbing drainage system when a negative pressure develops in the piping system. The device shall close by gravity under zero differential pressure and seal under conditions of back pressure.
�3. Reference Standard RS-16 of the appendix to chapter one of title twenty-seven of the administrative code of the city of New York is amended by adding a new section P109.12 to read as follows:
P109.12 AIR ADMITTANCE VALVES
(a) Where permitted. The use of air admittance valves in lieu of providing a vent stack through the roof shall be permitted in dwellings three stories or less in height. An individual vent pipe, branch vent, vent stack or stack vent shall be permitted to terminate with a connection to an air admittance valve. Air admittance valves shall be installed in accordance with the manufacturer's installations and this section.
(b) Individual and branch type air admittance valves. Individual and branch type air admittance valves shall conform to ANSI-ASSE 1051. Individual and branch type air admittance valves shall only vent fixtures located on the same floor level.
(c) Stack type air admittance valves. Stack type air admittance valves shall conform to ASSE 1050. Stack type air admittance valves shall be permitted to vent fixtures on different floor levels.
(d) Location. Individual and branch type air admittance valves shall be located a minimum of four inches above the weir of the ban. Stack type air admittance valves shall be located a minimum of six inches above the flood level rim of the highest fixtures being vented and a minimum of six inches above building insulation material. Air admittance valves shall be located within the maximum developed length permitted for the vent piping.
(e) Access and ventilation. All air admittance valves shall be accessible and located within a ventilated space that allows air to enter the valve.
(f) Size. The air admittance valve shall be rated for the diameter size of the pipe to which it is connected.
(g) Vent to outdoors. A minimum of one four inch stack shall extend outdoors to the open air for every plumbing system.
(h) Limitation of installation. Air admittance valves shall not be located within supply or return air plenums. Air admittance valves shall not be used to provide a flow of air to a sewage ejector.
�4. This local law shall take effect immediately.