Int 0999-2009
Site safety managers and coordinators.
IntroductionEnactedCommittee on Housing and Buildingsintroduced 2009-05-20Local Law 2009/059
Enacted as Local Law 2009/059.
Official record · Legistar
Agenda: 2009-05-20Passed: 2009-09-03Enacted: 2009-09-03
Committee on Housing and Buildings — Department of Housing Preservation and Development, Department of Buildings and rent regulation.
How it compares
34% of similar bills passed
17 passed · 33 died
This bill: 90 days in committee
Similar bills: median 551 days · 125 days when passed
Compared against 50 Introduction bills in Committee on Housing and Buildings.
Ranked by how closely each matches this bill's topic — closest first:
Int 0747-2008
Site safety managers and site safety coordinators.
624dFiled
Int 0783-2008
Site safety personnel, including concrete site safety managers.
45dEnacted
Int 0885-2012
Construction site fire safety managers.
551dFiled
Int 0329-2006
Requiring construction site safety coordinators on demolition sites.
1331dFiled
Int 0253-2004
Requiring construction site safety coordinators on demolition sites.
660dFiled
Int 0073-2002
Requiring construction site safety coordinators on demolition sites.
657dFiled
+ 44 more comparable bills
Sponsors (21)
Lifecycle
IntroducedIntroduced by Council
2009-05-20 · City Council
ActionReferred to Comm by Council
2009-05-20 · City Council
HeardHearing Held by Committee
2009-06-08 · Committee on Housing and Buildings
HeldLaid Over by Committee
2009-06-08 · Committee on Housing and Buildings
HeardHearing Held by Committee
2009-08-19 · Committee on Housing and Buildings
ActionAmendment Proposed by Comm
2009-08-19 · Committee on Housing and Buildings
ActionAmended by Committee
2009-08-19 · Committee on Housing and Buildings
AdvancedApproved by Committee
2009-08-19 · Committee on Housing and Buildings
AdvancedApproved by Council
2009-08-20 · City Council
ActionSent to Mayor by Council
2009-08-20 · City Council
HeardHearing Held by Mayor
2009-09-03 · Mayor
AdvancedSigned Into Law by Mayor
2009-09-03 · Mayor
ActionRecved from Mayor by Council
2009-09-03 · City Council
Votes (13)
Aye (11)
Leroy G. Comrie, Jr.Rosie MendezJames S. OddoElizabeth S. CrowleyErik Martin DilanJoel RiveraJames VaccaLewis A. FidlerThomas White, Jr.Tony AvellaGale A. Brewer
Absent (2)
Maria BaezRobert Jackson
Heard at (4)
City Council · 2009-08-20 · 1:30 PM · Council Chambers - City Hall
Committee on Housing and Buildings · 2009-08-19 · 10:00 AM · Council Chambers - City Hall
Committee on Housing and Buildings · 2009-06-08 · 11:00 AM · Council Chambers - City Hall
City Council · 2009-05-20 · 1:30 PM · Council Chambers - City Hall
Attachments (12)
- Int. No. 999 - 5/20/09
- Witness List
- Committee Report 6/8/09
- Hearing Testimony 6/8/09
- Hearing Transcript 6/8/09
- Committee Report 8/19/09
- Hearing Transcript 8/19/09
- Committee Report - Stated Meeting 8/20/09
- Fiscal Impact Statement
- Mayor's Letter
- Hearing Transcript - Stated Meeting 8/20/09
- Local Law
Full text
Be it enacted by the Council as follows:
Section 1. Section 3310 of the New York city building code, as added by local law number 33 for the year 2007, is amended by adding a new section 3310.8.1.1 to read as follows:
3310.8.1.1 Site safety manager or coordinator standpipe inspection responsibilities. The site safety manager or coordinator shall, at a minimum, in accordance with rules promulgated by the department, conduct daily checks to ensure that a standpipe system is available and in a state of readiness at all times for use by fire fighting personnel, by verifying:
1. That valves are in place at each story below the construction floor;
2. That standpipes are connected to a water source or siamese connection; and
3. That siamese hose connections are free from obstruction and are marked by a red light and sign that reads, “Standpipe Siamese Connection.”
The site safety manager or coordinator shall also, in accordance with such rules, conduct weekly checks to verify that no breach exists by visually tracing the standpipe, including risers, cross connections and siamese connections. A record of all such inspections shall be maintained by such site safety manager or coordinator in a log book.
§ 2. This local law shall take effect immediately.
8/12/2009 6:38 PM