Int 0262-2010
Reducing unnecessary artificial lighting in lobbies and hallways.
IntroductionEnactedCommittee on Housing and Buildingsintroduced 2010-06-09Local Law 2010/047
Enacted as Local Law 2010/047.
Official record · Legistar
Agenda: 2010-06-09Passed: 2010-10-06Enacted: 2010-10-06
Committee on Housing and Buildings — Department of Housing Preservation and Development, Department of Buildings and rent regulation.
How it compares
28% of similar bills passed
14 passed · 36 died
This bill: 110 days in committee
Similar bills: median 455 days · 110 days when passed
Compared against 50 Introduction bills in Committee on Housing and Buildings.
Ranked by how closely each matches this bill's topic — closest first:
Int 0277-2010
Improving lighting efficiency in dwellings.
110dEnacted
Int 0257-2004
Emergency lighting and exit signs.
660dFiled
Int 0612-2003
Emergency lighting and exit signs.
41dFiled
Int 1100-2013
Keeping residential stairwells and hallways lit during blackouts.
190dFiled
Int 0524-1999
Illuminated Pathways and Signs
1021dFiled
Int 1182-2013
Construction site lighting.
62dFiled
+ 44 more comparable bills
Sponsors (24)
Lifecycle
IntroducedIntroduced by Council
2010-06-09 · City Council
ActionReferred to Comm by Council
2010-06-09 · City Council
HeardHearing Held by Committee
2010-06-22 · Committee on Housing and Buildings
HeldLaid Over by Committee
2010-06-22 · Committee on Housing and Buildings
HeardHearing Held by Committee
2010-09-28 · Committee on Housing and Buildings
ActionAmendment Proposed by Comm
2010-09-28 · Committee on Housing and Buildings
ActionAmended by Committee
2010-09-28 · Committee on Housing and Buildings
AdvancedApproved by Committee
2010-09-28 · Committee on Housing and Buildings
AdvancedApproved by Council
2010-09-29 · City Council
HeardHearing Held by Mayor
2010-10-06 · Mayor
AdvancedSigned Into Law by Mayor
2010-10-06 · Mayor
ActionRecved from Mayor by Council
2010-10-06 · City Council
Votes (14)
Aye (10)
Melissa Mark-ViveritoLewis A. FidlerRobert JacksonLetitia JamesBrad S. LanderEric A. UlrichJumaane D. WilliamsErik Martin DilanRosie MendezElizabeth S. Crowley
Absent (4)
Gale A. BrewerJoel RiveraJames S. OddoLeroy G. Comrie, Jr.
Heard at (4)
City Council · 2010-09-29 · 1:30 PM · Emigrant Savings Bank - 49-51 Chambers Street
Committee on Housing and Buildings · 2010-09-28 · 1:00 PM · 250 Broadway - Committee Rm, 14th Fl.
Committee on Housing and Buildings · 2010-06-22 · 1:00 PM · 250 Broadway - Hearing Room, 14th Fl.
City Council · 2010-06-09 · 1:30 PM · Council Chambers - City Hall
Attachments (11)
- Int. No. 262 - 6/9/10
- Committee Report 6/22/10
- Hearing Testimony 6/22/10 - Bomee Jung
- Hearing Testimony 6/22/10
- Hearing Transcript 6/22/10
- Committee Report 9/28/10
- Committee Report - Stated Meeting
- Fiscal Impact Statement
- Mayor's Letter
- Hearing Transcript - Stated Meeting 9-29-10
- Local Law 47
Full text
Be it enacted by the Council as follows:
Section 1. Statement of findings and purpose. The Council finds that current egress illumination requirements for lobbies and hallways under the New York city building code result in the electric lighting of egress spaces that are either sufficiently lit by daylight or that are unoccupied. The Council therefore finds that energy could be saved by reducing such excessive lighting requirements for such spaces.
§2. Section BC 202 of the New York city building code is amended by adding certain definitions to be placed in appropriate alphabetical order to read as follows:
OCCUPANT SENSOR. A device that detects the presence or absence of people within an area and causes lighting, equipment, or appliances to be regulated accordingly.
PHOTOSENSOR. A device that detects the presence of visible light.
§3. Sections BC 1006.1 and BC 1006.2 of the New York city building code, as added by local law number 33 for the year 2007, are amended to read as follows:
1006.1 Illumination Required. Exits, exit discharges, and public corridors shall be illuminated at all times by either daylight or electric lighting fixtures. Exit access components shall be illuminated by either daylight or electric lighting fixtures at all times [during occupancy] that the space served by the exit access component is occupied.
Exceptions:
1. Occupancies in Group U.
2. Aisle accessways in Group A.
3. Dwelling units and sleeping units in Groups I-1, R-1, R-2 and R-3.
4. Sleeping units of Group I occupancies.
1006.2 Illumination level. The means of egress illumination level shall not be less than [2 foot-candles (22 lux) at the floor level in exits, at exit discharges, and in public corridors, and shall not be less than 1 foot-candle (11 lux) at the floor level in exit access components other than public corridors] 1 foot-candle (11 lux) at the walking surface level.
Exceptions:
1. For auditoriums, theaters, concert or opera halls and similar assembly occupancies, the illumination at the floor level is permitted to be reduced during performances to not less than 0.5 foot-candle (5.38 lux) for aisles and cross aisles, and 0.2 foot-candle (2.15 lux) for other portions of the space, provided that the required illumination is automatically restored upon activation of a premise’s fire alarm system where such system is provided. Step lights shall be provided in accordance with Section 1024.11.4.
2. Safe areas in assembly occupancies shall be illuminated in accordance with Section 1024.17.3.2.
3. Open exterior spaces used to receive occupants as Class 1 or 2 exits in assembly occupancies shall be illuminated in accordance with Section 1024.17.4.
4. In exits in buildings that contain photoluminescent exit path markings tested in laboratory conditions with 2 foot-candles (22 lux) of activating illumination, the illumination level shall not be less than 2 foot-candles (22 lux).
§4. Section BC 1006 of the New York city building code is amended by adding a new section 1006.2.1 to read as follows:
1006.2.1 Sensors and Controls. Automatic, occupant sensor or photosensor lighting controls shall be permitted within means of egress, provided that the illumination level is not reduced to a level below the minimum requirements of section 1006.2 of this code, and the switch controllers are equipped for fail-safe operation ensuring that if the sensor or control fails, the lighting levels will be at the levels required by 1006.2 of this code.
§5. This local law shall take effect on January 1, 2011, except that the commissioner of buildings shall take such actions as are necessary for its implementation, including the promulgation of rules, prior to such effective date.
.
LS 1001
9/21/2010 5:19 PM