Int 1100-2013
Keeping residential stairwells and hallways lit during blackouts.
IntroductionFiledCommittee on Housing and Buildingsintroduced 2013-06-24
Filed — closed without being enacted.
Official record · Legistar
Agenda: 2013-06-24Passed: 2013-12-31
Committee on Housing and Buildings — Department of Housing Preservation and Development, Department of Buildings and rent regulation.
How it compares
30% of similar bills passed
15 passed · 35 died
This bill: 190 days in committee
Similar bills: median 284 days · 110 days when passed
Compared against 50 Introduction bills in Committee on Housing and Buildings.
Ranked by how closely each matches this bill's topic — closest first:
Int 0262-2010
Reducing unnecessary artificial lighting in lobbies and hallways.
110dEnacted
Int 0263-2014
Construction site lighting.
18dEnacted
Int 1182-2013
Construction site lighting.
62dFiled
Int 0612-2003
Emergency lighting and exit signs.
41dFiled
Int 0257-2004
Emergency lighting and exit signs.
660dFiled
Int 0878-2012
Retroactively requiring back-up emergency lighting for egress paths and elevators.
566dFiled
+ 44 more comparable bills
Sponsors (22)
Lifecycle
IntroducedIntroduced by Council
2013-06-24 · City Council
ActionReferred to Comm by Council
2013-06-24 · City Council
HeardHearing Held by Committee
2013-06-27 · Committee on Housing and Buildings
HeldLaid Over by Committee
2013-06-27 · Committee on Housing and Buildings
HeardHearing Held by Committee
2013-06-27 · Committee on Environmental Protection
HeldLaid Over by Committee
2013-06-27 · Committee on Environmental Protection
HeardHearing Held by Committee
2013-06-27 · Committee on Parks and Recreation
HeldLaid Over by Committee
2013-06-27 · Committee on Parks and Recreation
HeardHearing Held by Committee
2013-06-27 · Committee on Transportation
HeldLaid Over by Committee
2013-06-27 · Committee on Transportation
HeardHearing Held by Committee
2013-06-27 · Committee on Waterfronts
HeldLaid Over by Committee
2013-06-27 · Committee on Waterfronts
ClosedFiled (End of Session)
2013-12-31 · City Council
Heard at (4)
Committee on Parks and Recreation · 2013-06-27 · 10:00 AM · Council Chambers - City Hall
Committee on Environmental Protection · 2013-06-27 · 10:00 AM · Council Chambers - City Hall
Committee on Housing and Buildings · 2013-06-27 · 10:00 AM · Council Chambers - City Hall
City Council · 2013-06-24 · 1:30 PM · Council Chambers - City Hall
Attachments (3)
Full text
Be it enacted by the Council as follows:
Section 1. Section BC 1002 of the New York city building code is amended by adding a new definition to be placed in alphabetical order to read as follows:
LUMENS. The unit of luminous flux, equal to the luminous flux emitted in a unit solid angle by a point source of one candle intensity.
§ 2. Section BC 1006 of the New York city building code is amended by adding a new subdivision 1006.4 to read as follows:
1006.4 Backup lighting system. Exit access corridors, exit passageways, exit stairways, and interior exit discharge elements serving occupancies in Groups I-1, R-1, and R-2 shall be provided with a backup lighting system in accordance with Section 1006.4.1 and Section 1006.4.2.
Exceptions:
1. Buildings in Group R-2 occupancy that are four stories or less and do not contain more than three dwelling units per story.
2. Where the emergency power source for the illumination required in Section 1006.3 is an on-site generator utilizing natural gas from the public utility street main as a fuel supply, as permitted in Section 2702.
3. Any level of a stairwell that is provided with not less than 12 square feet of exterior glazed opening facing onto a public way, or onto a yard or court.
4. Public corridors that are provided with exterior glazed openings facing onto a public way, or onto a yard or court. The net glazed area shall not be less than 6 percent of the floor area of the corridor.
1006.4.1 Backup lighting system power source. The power supply from the backup lighting system power source shall be available no later than 10 seconds after the building’s emergency power system fails and shall last for a duration of not less than 120 hours.
1006.4.2 Performance of backup lighting system. Not less than 60 lumens of light output shall be provided at each stairway entrance and discharge. Not less than 60 lumens of light output shall be provided at every 30 feet of public corridor. The backup lighting system shall be designed and installed so that the failure of any individual lighting element shall not leave in total darkness any space the requires emergency illumination.
§ 3. This local law shall take effect January 1, 2014.
JCH
6/21/2013 12:56 PM