← All bills

Int 0273-2010

Lighting of temporary walkways, foot bridges and sidewalk sheds at construction sites.

IntroductionEnactedCommittee on Housing and Buildingsintroduced 2010-06-09Local Law 2010/051

Enacted as Local Law 2010/051.

Official record · Legistar

Agenda: 2010-06-09Passed: 2010-10-06Enacted: 2010-10-06
Committee on Housing and BuildingsDepartment of Housing Preservation and Development, Department of Buildings and rent regulation.

How it compares

30% of similar bills passed

15 passed · 35 died

This bill: 110 days in committee

Similar bills: median 553 days · 104 days when passed

Sponsors (24)

Lifecycle

IntroducedIntroduced by Council
2010-06-09 · City Council
ActionReferred to Comm by Council
2010-06-09 · City Council
HeardHearing Held by Committee
2010-06-22 · Committee on Housing and Buildings
HeldLaid Over by Committee
2010-06-22 · Committee on Housing and Buildings
HeardHearing Held by Committee
2010-09-28 · Committee on Housing and Buildings
ActionAmendment Proposed by Comm
2010-09-28 · Committee on Housing and Buildings
ActionAmended by Committee
2010-09-28 · Committee on Housing and Buildings
AdvancedApproved by Committee
2010-09-28 · Committee on Housing and Buildings
AdvancedApproved by Council
2010-09-29 · City Council
ActionSent to Mayor by Council
2010-09-29 · City Council
HeardHearing Held by Mayor
2010-10-06 · Mayor
AdvancedSigned Into Law by Mayor
2010-10-06 · Mayor
ActionRecved from Mayor by Council
2010-10-06 · City Council

Votes (14)

Aye (10)
Melissa Mark-ViveritoElizabeth S. CrowleyErik Martin DilanLewis A. FidlerRobert JacksonBrad S. LanderEric A. UlrichJumaane D. WilliamsLetitia JamesRosie Mendez
Absent (4)
Gale A. BrewerJames S. OddoJoel RiveraLeroy G. Comrie, Jr.

Heard at (4)

City Council · 2010-09-29 · 1:30 PM · Emigrant Savings Bank - 49-51 Chambers Street
Committee on Housing and Buildings · 2010-09-28 · 1:00 PM · 250 Broadway - Committee Rm, 14th Fl.
Committee on Housing and Buildings · 2010-06-22 · 1:00 PM · 250 Broadway - Hearing Room, 14th Fl.
City Council · 2010-06-09 · 1:30 PM · Council Chambers - City Hall

Attachments (11)

Full text
Be it enacted by the Council as follows: Section 1. Section BC 3307.2.1 of the New York city building code, as added by local law number 33 for the year 2007, is amended to read as follows: 3307.2.1 Temporary walkways. Temporary walkways shall comply with the following: 1. Temporary walkways shall be of sufficient width to accommodate the pedestrian traffic, but in no case shall it be less than 5 feet (1524 mm) in width, and shall be provided with a durable walking surface. 2. All temporary walkways shall be illuminated at all times either by [natural] daylight or [artificial] electric light. The level of illumination shall be [the equivalent of that produced by 200 watt, 3400 lumen minimum, standard incandescent lamps enclosed in vandal-proof fixtures and spaced 15 feet (4572 mm) apart and 8 feet (2438 mm) above the floor level] a minimum of 1 foot-candle (11 lux) measured at the level of the walking surface. All lamps shall be enclosed in vandal-proof fixtures, have a minimum luminous efficacy of 45 lumens per watt or greater and be rated to operate at temperatures of 5 degrees Fahrenheit and higher. [Artificial] Electric lighting units shall be inspected [nightly] daily; and burned out or inoperative units shall be replaced or repaired immediately. Photosensors may be used to control electric lighting according to the amount of daylight available. All photosensors shall be equipped for fail-safe operation ensuring that if the sensor or control fails, the lamps will provide the lighting levels required by this section. 3. Temporary walkways shall be provided with adequate slopes so that they are accessible and shall be designed to support all imposed loads, and in no case shall the design live load be less than 150 pounds per square foot (732.3 kg/m2). 4. Where permission has been granted by the Department of Transportation to locate a temporary walkway beyond the curb line, such temporary walkway shall be provided with a guardrail in accordance with the Department of Transportation’s requirements. §2. Section BC 3307.2.2 of the New York city building code, as added by local law number 33 for the year 2007, is amended to read as follows: 3307.2.2 Foot bridges. Foot bridges shall comply with the following: 1. Foot bridges shall be of sufficient width to accommodate the pedestrian traffic, but in no case shall it be less than 5 feet (1524 mm) in width, and shall be provided with a durable walking surface. 2. All foot bridges shall be illuminated at all times either by [natural] daylight or [artificial] electric light. The level of illumination shall be [the equivalent of that produced by 200 watt, 3400 lumen minimum, standard incandescent lamps enclosed in vandal-proof fixtures and spaced 15 feet (4572 mm) apart and 8 feet (2438 mm) above the floor level] a minimum of 1 foot-candle (11 lux) measured at the level of the sidewalk walking surface. All lamps shall be enclosed in vandal-proof fixtures, shall have a minimum luminous efficacy of 45 lumens per watt or greater, and be rated to operate at temperatures of 5 degrees Fahrenheit and higher. [Artificial] Electric lighting units shall be inspected [nightly] daily; and burned out or inoperative units shall be replaced or repaired immediately. Photosensors may be used to control electric lighting according to the amount of daylight available. All photosensors shall be equipped for fail-safe operation ensuring that if the sensor or control fails, the lamps will provide the lighting levels required by this section. 3. Foot bridges shall be provided with adequate slopes so that they are accessible and shall be designed to support all imposed loads and in no case shall the design live load be less than 150 pounds per square foot (732.3 kg/m2). The walkway on such bridge shall be provided with guardrails for its entire length and shall have cleats to prevent slipping. Where planks are used to pave the walkway, they shall be laid close and securely fastened to prevent displacement. Planks shall be of uniform thickness, and all exposed ends on ramps shall be provided with beveled fillers to eliminate tripping hazards. §3. Item 2 of section BC 3307.6.5 of the New York city building code, as added by local law number 33 for the year 2007, is amended to read as follows: 2. The underside of sidewalk sheds shall be lighted at all times either by [natural] daylight or [artificial] electric light. The level of illumination shall be [the equivalent of that produced by 200 watt, 3400 lumen minimum, standard incandescent lamps enclosed in vandal-proof fixtures and spaced 15 feet (4572 mm) apart and 8 feet (2438 mm) above the floor level] a minimum of 1 foot-candle (11 lux) measured at the level of the sidewalk walking surface. All lamps shall be enclosed in vandal-proof fixtures, have a minimum luminous efficacy of 45 lumens per watt or greater, and be rated to operate at temperatures of 5 degrees Fahrenheit and higher. [Artificial]Electric lighting units shall be inspected [nightly] daily; and burned out or inoperative units shall be replaced or repaired immediately. Photosensors may be used to control electric lighting according to the amount of daylight available. All photosensors shall be equipped for fail-safe operation ensuring that if the sensor or control fails, the lamps will provide the lighting levels required by this section. §4. This local law shall take effect on July 1, 2011, except that the commissioner of buildings shall take such measures as are necessary for its implementation, including the promulgation of rules, prior to such effective date. 9-21-10 5 pm