Int 0604-2018

Fire Safety Package - Requirements for smoke alarms and smoke detectors in residential and non-residential occupancies.

IntroductionEnactedCommittee on Housing and Buildingsintroduced 2018-02-15Local Law 2018/113

Enacted as Local Law 2018/113.

Official record · Legistar

Agenda: 2018-02-15Passed: 2018-06-09Enacted: 2018-06-09

Summary

This bill would require that, where a smoke alarm or detector is within an area of 20 feet from a stationary or fixed cooking appliance in all residential buildings, after January 1, 2021, that smoke alarms must be listed in accordance with the 8th edition of UL 217, and smoke detectors must be listed in accordance with the 7th edition of UL 268.

Committee on Housing and BuildingsDepartment of Housing Preservation and Development, Department of Buildings and rent regulation.

How it compares

30% of similar bills passed

15 passed · 35 died

This bill: 81 days in committee

Similar bills: median 513 days · 81 days when passed

Sponsors (3)

Lifecycle

IntroducedIntroduced by Council
2018-02-15 · City Council
ActionReferred to Comm by Council
2018-02-15 · City Council
HeardHearing Held by Committee
2018-02-26 · Committee on Housing and Buildings
HeldLaid Over by Committee
2018-02-26 · Committee on Housing and Buildings
HeardHearing Held by Committee
2018-02-26 · Committee on Fire and Emergency Management
HeldLaid Over by Committee
2018-02-26 · Committee on Fire and Emergency Management
HeardHearing Held by Committee
2018-05-07 · Committee on Housing and Buildings
ActionAmendment Proposed by Comm
2018-05-07 · Committee on Housing and Buildings
ActionAmended by Committee
2018-05-07 · Committee on Housing and Buildings
AdvancedApproved by Committee
2018-05-07 · Committee on Housing and Buildings
AdvancedApproved by Council
2018-05-09 · City Council
ActionSent to Mayor by Council
2018-05-09 · City Council
HeardHearing Scheduled by Mayor
2018-05-29 · Mayor
AdvancedCity Charter Rule Adopted
2018-06-09 · Administration
ActionReturned Unsigned by Mayor
2018-06-12 · City Council

Votes (11)

Aye (11)
Carlina Rivera Robert E. Cornegy, Jr.Fernando Cabrera Margaret S. ChinRafael L. Espinal, Jr.Barry S. GrodenchikBill PerkinsHelen K. RosenthalRitchie J. TorresJumaane D. WilliamsMark Gjonaj

Heard at (5)

City Council · 2018-05-09 · 1:30 PM · Council Chambers - City Hall
Committee on Housing and Buildings · 2018-05-07 · 2:00 PM · Committee Room - City Hall
Committee on Fire and Emergency Management · 2018-02-26 · 10:00 AM · Council Chambers - City Hall
Committee on Housing and Buildings · 2018-02-26 · 10:00 AM · Council Chambers - City Hall
City Council · 2018-02-15 · 1:30 PM · Council Chambers - City Hall

Attachments (19)

Full text
Be it enacted by the Council as follows: Section 1. Article 312 of chapter 3 of title 28 of the administrative code of the city of New York is amended by adding a new section 28-312.8 to read as follows: � 28-312.8 Location of smoke alarms and smoke detectors. On or after January 1, 2021, smoke alarms and smoke detectors installed or replaced in group R occupancies shall be installed in accordance with section 907.2.11.5 of the New York city building code. � 2. Chapter 9 of the New York city building code is amended by adding a new section 907.2.11.5 to read as follows: 907.2.11.5 Smoke alarms and smoke detectors in group R occupancies. On and after January 1, 2021, smoke alarms and smoke detectors shall not be installed or replaced in an individual dwelling or sleeping unit, including dwellings or units in prior code buildings, within an area of exclusion determined by a 20 foot (6.0 m) radial distance along a horizontal flow path from a stationary or fixed cooking appliance, unless listed in accordance with the 8th edition of UL 217 for smoke alarms or the 7th edition of UL 268 for smoke detectors. � 3. Appendix Q of the New York city building code is amended by adding a new section BC Q107 to read as follows: SECTION BC Q107 INSTALLATION OF FIRE ALARMS Q107.1 General. Fire alarms, where required by this code, shall be installed in accordance with NFPA 72, National Fire Alarm and Signaling Code, 2010 edition, modified for New York City as set forth below. Refer to the rules of the department for any other additions, modifications or deletions that may have been made to this standard in accordance with Section 28-103.19 of the Administrative Code. 29.8.3.4(4) Delete and replace with the following: Smoke alarms and smoke detectors shall not be installed within an area of exclusion determined by a 10 ft (3.0 m) radial distance along a horizontal flow path from a stationary or fixed cooking appliance, unless listed for installation in close proximity to cooking appliances. Smoke alarms and smoke detectors installed between 10 ft (3.0 m) and 20 ft (6.1 m) along a horizontal flow path from a stationary or fixed cooking appliance shall be equipped with an alarm-silencing means or use photoelectric detection. On and after January 1, 2021, the requirements of this section shall apply only to occupancy groups other than group R. Exception: Smoke alarms or smoke detectors that use photoelectric detection shall be permitted for installation at a radial distance greater than 6 ft (1.8 m) from any stationary or fixed cooking appliance when the following conditions are met: (a) The kitchen or cooking area and adjacent spaces have no clear interior partitions or headers; and (b) The 10ft (3.0 m) area of exclusion would prohibit the placement of a smoke alarm or smoke detector required by other sections of this code. � 4. This local law takes effect immediately. MPC LS 5685 5/1/18 4:52pm 2